Copyright © The 18th International Conference on Electrorheological Fluids and Magnetorheological Suspensions
Powered by
Aconf.org
, One-stop Solutions for Academic Events
Start Time:2023-06-11 15:00 (Asia/Shanghai)
Duration:15min
Session:[S2] Concurrent Session 2 » [S2-7] Concurrent Session 2-7 & 2-8
No files
The dynamic concentration changes of MRF during self homogenization were measured using a in-situ monitoring method based on the inductance sensing. The experimental results show that the MR rotary actuator with self homogenization function can resume normal operation within 60s after adding completely failed MRF, and the uniformity of MRF increased by 1800% compared to the initial failure state. We believe that this study establishes a route for the solution of MRF’s sedimentation, and is significant in improving the robust performance of MR rotary actuators and expanding the application boundaries of MR materials.